posted on 2024-06-02, 22:46 authored by Ali Zafari, Ameen GargoomAmeen Gargoom, Nasser Hosseinzadeh, Shama IslamShama Islam, Enamul HaqueEnamul Haque, Mohammad Taufiqul ArifMohammad Taufiqul Arif, Mohamed AbdelrazekMohamed Abdelrazek
This paper proposes a hierarchical multi-stage approach based on a distributed level phasor measurement unit (µPMU) at local controllers and a phasor data concentrator (PDC) at the central control unit to restore system voltage when it exceeds the limits recommended by the IEEE 1547-2018 standard. The proposed algorithm does not need an accurate system model or employ optimization solutions. Therefore, it has less implementation complexity and would be popular among distribution network service providers (DNSPs) and distribution network operators (DNOs) as it does not suffer from cost and computational complexity limitations. A PMU-PDC-based communication platform has been developed as a more efficient alternative to the supervisory control and data acquisition (SCADA) system, and provides superior characteristics, including a higher sample rate, higher data resolutions, and faster communication. The proposed coordinated algorithm aims to postpone power generation curtailment in distributed energy resources (DERs) with overvoltage problems (local DERs) by incorporating all the DERs that are not subjected to voltage violation (remote DERs) by absorbing their maximum reactive power capacity. If the system voltage has not recovered after absorbing all of the reactive power capacity of all the DERs, a reduced active power curtailment proposed by the algorithm is then applied to the system to control the voltage. The proposed strategy has been simulated in MATLAB and applied to IEEE 13-bus and IEEE 33-bus radial distribution benchmark systems to validate the performance of the system, in terms of its ability to coordinate voltage control and the accuracy of the PMU-PDC-based communication interface.

History

Journal

ENERGIES

Volume

16

Article number

ARTN 4650

Pagination

1-22

Location

Basel, Switzerland

eISSN

1996-1073

Language

English

Publication classification

C1 Refereed article in a scholarly journal

Issue

12

Publisher

MDPI

Usage metrics

    Research Publications

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC