Deakin University
Browse

A simplified stroke rehabilitation assessment of movement instrument

Download (726.03 kB)
journal contribution
posted on 2006-07-01, 00:00 authored by I P Hseuh, W C Wang, C H Wang, C F Shen, Sing Lo, J H Lin, C L Hsieh
Background and Purpose. An efficient, reliable, and valid instrument for assessing motor function in patients with stroke is needed by both clinicians and researchers. To improve administration efficiency, we applied the multidimensional Rasch model to the 30-item, 3-subscale Stroke Rehabilitation Assessment of Movement (STREAM) instrument to produce a concise, reliable, and valid instrument (simplified STREAM [S-STREAM]) for measuring motor function in patients with stroke. Subjects and Methods. The STREAM (consisting of 3 subscales: upper-limb movements, lower-limb movements, and mobility) was administered to 351 subjects with first stroke occurrence and a median time after stroke of 19.5 months. The unidimensionality of each subscale of the STREAM first was verified with unidimensional Rasch analysis. Each subscale of the STREAM then was simplified by deleting redundant items on the basis of expert opinion and the results of the Rasch analysis. The Rasch reliability of the S-STREAM and the concurrent validity of the S-STREAM with the STREAM were examined with multidimensional Rasch analysis and the intraclass correlation coefficient (ICC), respectively. Results. After deleting the items that did not fit the Rasch model, we found that the 8-item upper-limb movement subscale, the 9-item lower-limb movement subscale, and the 10-item mobility subscale assessed single, unidimensional upper-limb movements, lower-limb movements, and mobility, respectively. We selected 5 items from each subscale to construct the S-STREAM and found that the reliability of each subscale of the resulting simplified instrument was high (Rasch reliability coefficients of [greater than or equal to] .91). The agreement between the subscale scores (Rasch estimates) of the S-STREAM and those of the STREAM was excellent (ICC of [greater than or equal to] .99, with a lower limit for the 95% confidence interval of [greater than or equal to] .985), indicating good concurrent validity of the S-STREAM with the STREAM. Discussion and Conclusion. The S-STREAM demonstrates high Rasch reliability, unidimensionality, and concurrent validity with the STREAM in patients with stroke. Furthermore, the S-STREAM is efficient to administer, as it consists of only half the number of items in the original STREAM. Additional studies to examine other psychometric properties (eg, predictive validity and responsiveness) of the S-STREAM or its psychometric properties in various recovery stages after stroke are needed to further establish its utility in both clinical and research settings.

History

Journal

Physical therapy

Volume

86

Pagination

936 - 943

Location

Washington, DC

Open access

  • Yes

ISSN

0031-9023

eISSN

1538-6724

Language

eng

Publication classification

C1 Refereed article in a scholarly journal

Copyright notice

2006, American Physical Therapy Association

Usage metrics

    Research Publications

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC