This paper proposes a direct control strategy for an interior permanent magnet synchronous generator-based variable speedwind turbine. Inthis scheme, the requirement of the continuous rotorpositionis eliminatedas all the calculationsaredonein the stator reference frame. This scheme possesses advantages such as lesser parameter dependence and reduced number of controllers compared with the traditional indirect vector control scheme.The direct control scheme is simpler and can eliminate some of the drawbacks of traditional indirect vector control scheme. The proposed control scheme is implemented in MATLAB/SimPowerSystems and the results show that the controller can operate under constant and varying wind speeds. Finally, a sensorless speed estimator is implemented, which enables the wind turbine to operate without the mechanical speed sensor. The simulation and experimental results for the sensorless speed estimator are presented.
History
Journal
IEEE Transactions on Sustainable Energy
Volume
5
Pagination
354-362
Location
United States
ISSN
1949-3029
Language
eng
Publication classification
C Journal article, C1.1 Refereed article in a scholarly journal