posted on 2017-08-11, 00:00 authored by Mahboubeh Parastarfeizabadi, Abbas KouzaniAbbas KouzaniBACKGROUND: Millions of patients around the world are affected by neurological and psychiatric disorders. Deep brain stimulation (DBS) is a device-based therapy that could have fewer side-effects and higher efficiencies in drug-resistant patients compared to other therapeutic options such as pharmacological approaches. Thus far, several efforts have been made to incorporate a feedback loop into DBS devices to make them operate in a closed-loop manner. METHODS: This paper presents a comprehensive investigation into the existing research-based and commercial closed-loop DBS devices. It describes a brief history of closed-loop DBS techniques, biomarkers and algorithms used for closing the feedback loop, components of the current research-based and commercial closed-loop DBS devices, and advancements and challenges in this field of research. This review also includes a comparison of the closed-loop DBS devices and provides the future directions of this area of research. RESULTS: Although we are in the early stages of the closed-loop DBS approach, there have been fruitful efforts in design and development of closed-loop DBS devices. To date, only one commercial closed-loop DBS device has been manufactured. However, this system does not have an intelligent and patient dependent control algorithm. A closed-loop DBS device requires a control algorithm to learn and optimize the stimulation parameters according to the brain clinical state. CONCLUSIONS: The promising clinical effects of open-loop DBS have been demonstrated, indicating DBS as a pioneer technology and treatment option to serve neurological patients. However, like other commercial devices, DBS needs to be automated and modernized.
History
Journal
Journal of neuroengineering and rehabilitationVolume
14Article number
79Pagination
1 - 20Publisher
BioMed CentralLocation
London, Eng.Publisher DOI
eISSN
1743-0003Language
engPublication classification
C Journal article; C1 Refereed article in a scholarly journalCopyright notice
2017, The AuthorsUsage metrics
Categories
No categories selectedKeywords
deep rain simulationclosed-loop controlbiomarkersensorsignal conditioningstimulatordeep brain simulationScience & TechnologyTechnologyLife Sciences & BiomedicineEngineering, BiomedicalNeurosciencesRehabilitationEngineeringNeurosciences & NeurologyLOCAL-FIELD POTENTIALSCOORDINATED RESET NEUROMODULATIONNONHUMAN PRIMATE MODELSUBTHALAMIC NUCLEUSPARKINSONS-DISEASEDELAYED FEEDBACKELECTRICAL-STIMULATIONESSENTIAL TREMORNEXT-GENERATIONCONTROL-SYSTEM