Deakin University
Browse

Agreement of Sedentary Behavior Metrics Derived From Hip- and Thigh-Worn Accelerometers Among Older Adults: With Implications for Studying Physical and Cognitive Health

Download (28.89 MB)
journal contribution
posted on 2021-01-01, 00:00 authored by John Bellettiere, Fatima Tuz-Zahra, Jordan A Carlson, Nicky Ridgers, Sandy Liles, Mikael Anne Greenwood-Hickman, Rod L Walker, Andrea Z LaCroix, Marta M Jankowska, Dori E Rosenberg, Loki Natarajan
Little is known about how sedentary behavior (SB) metrics derived from hip- and thigh-worn accelerometers agree for older adults. Thigh-worn activPAL (AP) micro monitors were concurrently worn with hip-worn ActiGraph (AG) GT3X+ accelerometers (with SB measured using the 100 counts per minute [cpm] cut point; AG100cpm) by 953 older adults (age 77 ± 6.6, 54% women) for 4–7 days. Device agreement for sedentary time and five SB pattern metrics was assessed using mean error and correlations. Logistic regression tested associations with four health outcomes using standardized (i.e., z scores) and unstandardized SB metrics. Mean errors (AP − AG100cpm) and 95% limits of agreement were: sedentary time −54.7 [−223.4, 113.9] min/day; time in 30+ min bouts 77.6 [−74.8, 230.1] min/day; mean bout duration 5.9 [0.5, 11.4] min; usual bout duration 15.2 [0.4, 30] min; breaks in sedentary time −35.4 [−63.1, −7.6] breaks/day; and alpha −.5 [−.6, −.4]. Respective Pearson correlations were: .66, .78, .73, .79, .51, and .40. Concordance correlations were: .57, .67, .40, .50, .14, and .02. The statistical significance and direction of associations were identical for AG100cpm and AP metrics in 46 of 48 tests, though significant differences in the magnitude of odds ratios were observed among 13 of 24 tests for unstandardized and five of 24 for standardized SB metrics. Caution is needed when interpreting SB metrics and associations with health from AG100cpm due to the tendency for it to overestimate breaks in sedentary time relative to AP. However, high correlations between AP and AG100cpm measures and similar standardized associations with health outcomes suggest that studies using AG100cpm are useful, though not ideal, for studying SB in older adults.

History

Journal

Journal for the Measurement of Physical Behaviour

Volume

4

Pagination

79-88

Location

Champaign, Ill.

Open access

  • Yes

ISSN

2575-6605

eISSN

2575-6613

Language

eng

Publication classification

C1 Refereed article in a scholarly journal

Publisher

Human Kinetics

Usage metrics

    Research Publications

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC