Deakin University
Browse

File(s) under permanent embargo

An auto-switch for multisampling of a wire beam electrode corrosion monitoring system

journal contribution
posted on 1998-10-01, 00:00 authored by H Eren, A Lowe, Mike Yongjun TanMike Yongjun Tan, S Bailey, B Kinsella
An auto-switch device has been designed, constructed, and tested for multisensor corrosion measurements. The auto-switch is able to connect/disconnect the selected wire beam electrode and/or electrode pairs under computer control. A computer controlled analog switch-array consisting of 100 inputs has been used as an essential part of the switch bank. The switch-bank is an essential component of a corrosion-monitoring instrument that is expected to find wide application in industry. The performance of the switch-bank is discussed and its effect on the signals is illustrated.