Development of polydimethylsiloxane-microdiamond composite materials for application as sorptive devices
Version 2 2024-06-05, 00:54Version 2 2024-06-05, 00:54
Version 1 2020-06-01, 15:48Version 1 2020-06-01, 15:48
journal contribution
posted on 2024-06-05, 00:54 authored by CK Hasan, HJ Wirth, A Gooley, TW Lewis, Robert ShellieRobert Shellie, PN Nesterenko, B Paull© 2019 The development and application of non-porous and porous sorptive rods, comprised of polydimethylsiloxane–microdiamond (PDMS-MD) composites, is reported. The PDMS-MD composites were made porous using inorganic salt (NaCl and NaHCO3) particles as dissolvable templates. Materials with pore size of ~40 µm down to ~5 µm were produced. The advantages of incorporating up to ~60%microdiamond (2–4 µm) into PDMS included: (1) significant increase in the density, which saw the rods sink within the aqueous sample without addition of secondary metal or glass materials, (2) significant improvement in mechanical stability (the porous composite rods could be thermally treated multiple times before application, unlike porous PDMS), (3) increased thermal stability up to 450–500 °C with only 6% weight loss of volatile components, and (4) higher thermal conductivity, estimated to be 108% higher than for PDMS. The PDMS-MD investigated as a sorbent for extraction, followed by liquid desorption and GC-FID analysis. Recovery of the sorbent for test solutes, isoamyl acetate, ethyl hexanoate, ethyl octanoate, ethyl decanoate, and phenethyl acetate, was found to range from ~87% to >100, with RSD of 2.10–12.50% in synthetic wine samples. Non-porous composite rods provided similar % recoveries to a commercial sorptive device (PDMS Twister), whereas porous rods showed improved % recovery for most of the test solutes (>10–20%) when applied under similar conditions. The limits of detection (LOD) for the above solutes within the developed method ranged from 0.60 to 27.30 µg L−1). Application of the PDMS-MD-LD-GC-FID method to white wine samples demonstrated how the PDMS-MD composite material can be applied as a robust and an efficient sorptive phase for trace chemical analysis.
History
Journal
Journal of Chromatography AVolume
1613Article number
ARTN 460669Pagination
1 - 9Location
NetherlandsPublisher DOI
ISSN
0021-9673eISSN
1873-3778Language
EnglishPublication classification
C1 Refereed article in a scholarly journalPublisher
ELSEVIERUsage metrics
Categories
No categories selectedKeywords
Science & TechnologyLife Sciences & BiomedicinePhysical SciencesBiochemical Research MethodsChemistry, AnalyticalBiochemistry & Molecular BiologyChemistryCompositesMicrodiamondPolydimethylsiloxaneSorptionONION-LIKE CARBONNANODIAMONDFILLERSOILSILANIZATIONFABRICATIONEXTRACTION030199 Analytical Chemistry not elsewhere classified3401 Analytical chemistry3499 Other chemical sciencesTechnology
Licence
Exports
RefWorksRefWorks
BibTeXBibTeX
Ref. managerRef. manager
EndnoteEndnote
DataCiteDataCite
NLMNLM
DCDC