Interpretation of Post-operative Distal Humerus Radiographs After Internal Fixation: Prediction of Later Loss of Fixation

Version 2 2024-06-03, 16:35
Version 1 2016-10-20, 13:51
journal contribution
posted on 2024-06-03, 16:35 authored by FMAP Claessen, N Stoop, D Ring, JN Doornberg, TG Guitton, MPJ van den Bekerom, AB Spoor, A Chauhan, AL Wahegaonkar, AB Shafritz, AE Garcia G, AN Miller, A Barquet, A Kristan, T Apard, AD Armstrong, A Berner, A Jubel, BE Kreis, CG Babis, B Sutker, BW Sears, BM Nolan, BD Crist, BJ Cross, BP Wills, CJ Barreto, C Ekholm, C Swigart, CD Oliveira Miranda, C Manke, C Zalavras, CA Goldfarb, C Cassidy, CJ Walsh, CM Jones, C Garnavos, C Young, CL Moreno-Serrano, C Lomita, C Klostermann, DF van Deurzen, DA Rikli, D Polatsch, D Beingessner, D Drosdowech, D Eygendaal, M Patel, D Brilej, ET Walbeehm, EG Ballas, EF Ibrahim, E Melamed, E Stojkovska Pemovska, E Hofmeister, EM Hammerberg, FT Kaplan, F Suarez, CH Fernandes, F Lopez-Gonzalez, FL Walter, F Frihagen, GA Kraan, G Kontakis, GS Dyer, G Kohut, G Panagopoulos, GR Hernandez, G Porcellini, GJ Bayne, G Merrell, G DeSilva, GJ Della Rocca, HB Bamberger, H Broekhuyse, H Durchholz, IF Kodde, I McGraw, I Harris, I Pountos, JM Wiater, J Choueka, JE Kazanjian, JA Gillespie, J Biert, JC Fanuele, JW Johnson, JA Greenberg, J Abrams, J Hall, J Fischer, JH Scheer, J Itamura, JT Capo, J Braman, J Rubio, JA Ortiz, JE Filho, J Nolla, J Abboud
Purpose Stable fixation of distal humerus fracture fragments is necessary for adequate healing and maintenance of reduction. The purpose of this study was to measure the reliability and accuracy of interpretation of postoperative radiographs to predict which implants will loosen or break after operative treatment of bicolumnar distal humerus fractures. We also addressed agreement among surgeons regarding which fracture fixation will loosen or break and the influence of years in independent practice, location of practice, and so forth. Methods A total of 232 orthopedic residents and surgeons from around the world evaluated 24 anteroposterior and lateral radiographs of distal humerus fractures on a Web-based platform to predict which implants would loosen or break. Agreement among observers was measured using the multi-rater kappa measure. Results The sensitivity of prediction of failure of fixation of distal humerus fracture on radiographs was 63%, specificity was 53%, positive predictive value was 36%, the negative predictive value was 78%, and accuracy was 56%. There was fair interobserver agreement (k ¼ 0.27) regarding predictions of failure of fixation of distal humerus fracture on radiographs. Interobserver variability did not change when assessed for the various subgroups. Conclusions When experienced and skilled surgeons perform fixation of type C distal humerus fracture, the immediate postoperative radiograph is not predictive of fixation failure. Reoperation based on the probability of failure might not be advisable.

History

Journal

Journal of Hand Surgery

Volume

41

Pagination

e337-e341

Location

United States

ISSN

0363-5023

eISSN

1531-6564

Language

English

Publication classification

C1.1 Refereed article in a scholarly journal, C Journal article

Copyright notice

2016, American Society for Surgery of the Hand

Issue

10

Publisher

W B SAUNDERS CO-ELSEVIER INC