Multi-dimensional gas chromatography with a planar microfluidic device for the characterization of volatile oxygenated organic compounds
journal contribution
posted on 2012-09-14, 00:00 authored by J Luong, R Gras, H Cortes, Robert ShellieRobert ShellieOxygenated compounds like methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, acetaldehyde, crotonaldehyde, ethylene oxide, tetrahydrofuran, 1,4-dioxane, 1,3-dioxolane, and 2-chloromethyl-1,3-dioxolane are commonly encountered in industrial manufacturing processes. Despite the availability of a variety of column stationary phases for chromatographic separation, it is difficult to separate these solutes from their respective matrices using single dimension gas chromatography. Implemented with a planar microfluidic device, conventional two-dimensional gas chromatography and the employment of chromatographic columns using dissimilar separation mechanisms like that of a selective wall-coated open tubular column and an ionic sorbent column have been successfully applied to resolve twelve industrially significant volatile oxygenated compounds in both gas and aqueous matrices. A Large Volume Gas Injection System (LVGIS) was also employed for sample introduction to enhance system automation and precision. By successfully integrating these concepts, in addition to having the capability to separate all twelve components in one single analysis, features associated with multi-dimensional gas chromatography like dual retention time capability, and the ability to quarantine undesired chromatographic contaminants or matrix components in the first dimension column to enhance overall system cleanliness were realized. With this technique, a complete separation for all the compounds mentioned can be carried out in less than 15 min. The compounds cited can be analyzed over a range of 250 ppm (v/v) to 100 ppm (v/v) with a relative standard deviation of less than 5% (n=20) with high degree of reliability.
History
Journal
Journal of Chromatography AVolume
1255Pagination
216 - 220Publisher
ElsevierLocation
Amsterdam, The NetherlandsPublisher DOI
ISSN
0021-9673eISSN
1873-3778Language
engPublication classification
C1 Refereed article in a scholarly journalUsage metrics
Read the peer-reviewed publication
Categories
Keywords
Chromatography, GasMicrofluidic Analytical TechniquesOxidation-ReductionOxygenReproducibility of ResultsVolatile Organic CompoundsScience & TechnologyLife Sciences & BiomedicinePhysical SciencesBiochemical Research MethodsChemistry, AnalyticalBiochemistry & Molecular BiologyChemistryMDGCVolatile oxygenated compoundsLarge Volume Gas Injection System (LVGIS)CAPILLARY-FLOW TECHNOLOGYPRINCIPLESMODULATION