Deakin University
Browse

NS-HGlio: A generalizable and repeatable HGG segmentation and volumetric measurement AI algorithm for the longitudinal MRI assessment to inform RANO in trials and clinics

journal contribution
posted on 2023-10-06, 02:18 authored by Aly H Abayazeed, Ahmed Abbassy, Michael Mueeller, Michael Hill, Mohamed Qayati, Shady MohamedShady Mohamed, Mahmoud Mekhaimar, Catalina Raymond, Prachi Dubey, Kambiz Nael, Saurabh Rohatgi, Vaishali Kapare, Ashwini Kulkarni, Tina Shiang, Atul Kumar, Nicolaus Andratschke, Jonas Willmann, Alexander Brawanski, Reordan De Jesus, Ibrahim Tuna, Steve H Fung, Joseph C Landolfi, Benjamin M Ellingson, Mauricio Reyes
Abstract Background Accurate and repeatable measurement of high-grade glioma (HGG) enhancing (Enh.) and T2/FLAIR hyperintensity/edema (Ed.) is required for monitoring treatment response. 3D measurements can be used to inform the modified Response Assessment in Neuro-oncology criteria. We aim to develop an HGG volumetric measurement and visualization AI algorithm that is generalizable and repeatable. Methods A single 3D-Convoluted Neural Network, NS-HGlio, to analyze HGG on MRIs using 5-fold cross validation was developed using retrospective (557 MRIs), multicentre (38 sites) and multivendor (32 scanners) dataset divided into training (70%), validation (20%), and testing (10%). Six neuroradiologists created the ground truth (GT). Additional Internal validation (IV, three institutions) using 70 MRIs, and External validation (EV, single institution) using 40 MRIs through measuring the Dice Similarity Coefficient (DSC) of Enh., Ed. ,and Enh. + Ed. (WholeLesion/WL) tumor tissue and repeatability testing on 14 subjects from the TCIA MGH-QIN-GBM dataset using volume correlations between timepoints were performed. Results IV Preoperative median DSC Enh. 0.89 (SD 0.11), Ed. 0.88 (0.28), WL 0.88 (0.11). EV Preoperative median DSC Enh. 0.82 (0.09), Ed. 0.83 (0.11), WL 0.86 (0.06). IV Postoperative median DSC Enh. 0.77 (SD 0.20), Ed 0.78. (SD 0.09), WL 0.78 (SD 0.11). EV Postoperative median DSC Enh. 0.75 (0.21), Ed 0.74 (0.12), WL 0.79 (0.07). Repeatability testing; Intraclass Correlation Coefficient of 0.95 Enh. and 0.92 Ed. Conclusion NS-HGlio is accurate, repeatable, and generalizable. The output can be used for visualization, documentation, treatment response monitoring, radiation planning, intra-operative targeting, and estimation of Residual Tumor Volume among others.

History

Journal

Neuro Oncology Advances

Volume

5

Season

January-December

Article number

ARTN vdac184

Pagination

1-10

Location

Oxford, Eng.

ISSN

2632-2498

eISSN

2632-2498

Language

eng

Publication classification

C1 Refereed article in a scholarly journal

Issue

1

Publisher

Oxford University Press