posted on 2024-06-05, 04:31 authored by James GongJames Gong, MF Lambert, AR Simpson, AC Zecchin
Hydraulic transients (water hammer waves) can be used to excite a pressurized pipeline, yielding the frequency response diagram (FRD) of the system. The FRD of a pipeline system is useful for condition assessment and fault detection, because it is closely related to the physical properties of the pipeline. Most previous FRD-based leak detection techniques use the sinusoidal leak-induced pattern recorded on the FRD, either shown on the resonant responses or the antiresonant responses. In contrast, the technique reported in the current paper only uses the responses at the first three resonant frequencies to determine the location and size of a leak. The bandwidth of the excitation only needs to be five times that of the fundamental frequency of the tested pipeline, which is much less than the requirement in conventional FRD-based techniques. Sensitivity analysis and numerical simulations are performed to assess the robustness and applicable range of the proposed leak location technique. The proposed leak location technique is verified by both numerical simulations and by using an experimental FRD obtained from a laboratory pipeline. © 2013 American Society of Civil Engineers.

History

Journal

Journal of hydraulic engineering

Volume

139

Pagination

645-655

Location

Reston, Va.

ISSN

0733-9429

Language

eng

Publication classification

C1.1 Refereed article in a scholarly journal

Copyright notice

2013, ASCE

Issue

6

Publisher

American Society of Civil Engineers

Usage metrics

    Research Publications

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC