Use of a photographic manipulation tool to assess corneal vascular response

journal contribution
posted on 2012-02-01, 00:00 authored by J Woods, L Jones, Craig Woods, S Schneider, D Fonn
Purpose. Corneal vasculature change in contact lens wearers has been linked to the level of hypoxia within the cornea. To assess the impact a treatment has on limbal vessels, a sensitive method of measurement and quantification is required.

Methods. A group of 21 highly myopic, hydrogel wearers, with preexisting signs of corneal hypoxia, were enrolled into a study where they wore sifilcon A silicone hydrogel lenses (Dk/t = 117), on a daily wear basis for 9 months. At all scheduled visits, photographs were taken of the superior, inferior, temporal, and nasal limbal regions which were then imported into Adobe Photoshop. A red-free filter was applied to enhance the contrast of the blood columns. In each quadrant, the length of the longest visible blood column was measured and the blood columns that penetrated >0.5 mm into the cornea were counted. A control group of 11 non-lens wearers was recruited. Their photographs were taken at the beginning of the study and 9 months later. An independent, masked observer assessed the photographs.

Results. There was a significant decrease in the maximum penetration of the blood column in all quadrants (p < 0.001) from baseline to the 9-month visit (e.g., superior: baseline 0.84 ± 0.39 mm; 9 months 0.63 ± 0.20 mm). There was also significant reduction in the number of visible blood columns longer than 0.5 mm in each quadrant (p < 0.001) from baseline to 9 months in all quadrants (e.g., superior: baseline 14.0 ± 8.2; 9 months 6.5 ± 6.0). The control group showed no change over time for the maximum blood column length (p = 0.638) or the number of columns >0.5 mm (p = 0.341).

Conclusions. A group of highly myopic subjects exhibited reduction in the maximum length and number of blood columns in the cornea when refit with a highly permeable silicone hydrogel material. The use of photography, along with Adobe Photoshop software, provides a reliable way of measuring corneal vascular responses over time.

History

Journal

Optometry and vision science

Volume

89

Issue

2

Pagination

215 - 220

Publisher

Lippincott Williams & Wilkins

Location

Philadelphia, Pa.

ISSN

1040-5488

eISSN

1538-9235

Language

eng

Publication classification

C1.1 Refereed article in a scholarly journal

Copyright notice

2012, American Academy of Optometry

Usage metrics

    Research Publications

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC