Openly accessible

A novel method based on first principles to determine the accuracy and reliability of force measurements reported by bicycle power meters.

Worn, Ryan and Dwyer, Daniel 2019, A novel method based on first principles to determine the accuracy and reliability of force measurements reported by bicycle power meters., Journal of Science and Cycling, vol. 8, no. 1, pp. 26-31, doi: 10.28985/jsc.v8i1.396.

Attached Files
Name Description MIMEType Size Downloads

Title A novel method based on first principles to determine the accuracy and reliability of force measurements reported by bicycle power meters.
Author(s) Worn, Ryan
Dwyer, Daniel
Journal name Journal of Science and Cycling
Volume number 8
Issue number 1
Start page 26
End page 31
Total pages 6
Publisher Journal of Science and Cycling
Place of publication Pulianas, Spain
Publication date 2019
ISSN 2254-7053
Keyword(s) validity
crank angle
pedalling technique
Summary The accuracy and reliability of instrumented bicycle crank systems (i.e. power meters) is an important consideration for sport scientists who evaluate cycling performance and pedalling biomechanics. Many crank systems report power and or force/s on the left and right crank arms separately, or indexes of pedalling effectiveness, although crank systems that have genuinely independent force transducers on the left and right crank arms are rare. There is a need to be able to evaluate the accuracy and reliability of the measurements of power meters without the requirement for expensive and or complex instrumentation. The present study describes a relatively simple and novel method of assessing the accuracy and reliability of measures of crank angle, radial force and tangential force. The method is demonstrated in its application to an instrumented crank system (Axis Cranks ™). Reported crank forces were compared with actual applied forces to determine accuracy and some procedures used to assess the measurement of force were duplicated to determine reliability. The crank system measured crank angle with an average RMS error of 1.84 degrees across pedalling rates of 30-150 r/min. The absolute error of radial and tangential force measurements were 6% and 3.2% respectively (RMSE) and the relative error (accuracy of change in force) of radial and tangential force were 1.48% and 0.25% respectively (RMSE). Repeated measurements of force were found to be highly reliable (intra-class coefficient > 0.998). The method presented in this report could be used to evaluate the accuracy and reliability of other power meters and instrumented crank systems.
Language eng
DOI 10.28985/jsc.v8i1.396
Field of Research 1106 Human Movement and Sports Sciences
HERDC Research category C1 Refereed article in a scholarly journal
Persistent URL http://hdl.handle.net/10536/DRO/DU:30130830

Connect to link resolver
 
Unless expressly stated otherwise, the copyright for items in DRO is owned by the author, with all rights reserved.

Every reasonable effort has been made to ensure that permission has been obtained for items included in DRO. If you believe that your rights have been infringed by this repository, please contact drosupport@deakin.edu.au.

Versions
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 0 times in TR Web of Science
Scopus Citation Count Cited 0 times in Scopus
Google Scholar Search Google Scholar
Access Statistics: 9 Abstract Views, 2 File Downloads  -  Detailed Statistics
Created: Wed, 23 Oct 2019, 08:37:52 EST

Every reasonable effort has been made to ensure that permission has been obtained for items included in DRO. If you believe that your rights have been infringed by this repository, please contact drosupport@deakin.edu.au.